Difference between revisions of "1028.5 Laboratory Testing Guidelines for Sec 1028"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (updated link)
m (Per CM, removed archaic SiteManager info and replaced with AASHTOWARE info)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
 
This article establishes procedures for Laboratory testing and reporting of concrete drain
 
This article establishes procedures for Laboratory testing and reporting of concrete drain
tile.  Refer to [http://www.modot.mo.gov/business/standards_and_specs/Sec1028.pdf Sec 1028] for MoDOT's specifications.
+
tile.  Refer to [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1028] for MoDOT's specifications.
  
 
==1028.5.1 Procedure==
 
==1028.5.1 Procedure==
Tests consist of absorption only. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through SiteManager.
+
Tests consist of absorption only. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through AASHTOWARE Project (AWP).
  
 
==1028.5.2 Sample Record==
 
==1028.5.2 Sample Record==
The sample record shall be completed in SiteManager, as described in [[:Category:101 Standard Forms#Sample Record General Information| Sample Record General Information]] [[image:bulldozer.jpg|20px]], and shall indicate acceptance, qualified acceptance or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
+
The sample record shall be completed in AASHTOWARE Project (AWP), as described in [[:Category:101 Standard Forms#Sample Record, General|AWP MA Sample Record, General]], and shall indicate acceptance, qualified acceptance or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
  
 
[[Category:1028 Corrugated Polyvinyl Chloride Culvert Pipe]]
 
[[Category:1028 Corrugated Polyvinyl Chloride Culvert Pipe]]

Latest revision as of 08:58, 14 September 2021

This article establishes procedures for Laboratory testing and reporting of concrete drain tile. Refer to Sec 1028 for MoDOT's specifications.

1028.5.1 Procedure

Tests consist of absorption only. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through AASHTOWARE Project (AWP).

1028.5.2 Sample Record

The sample record shall be completed in AASHTOWARE Project (AWP), as described in AWP MA Sample Record, General, and shall indicate acceptance, qualified acceptance or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.