Difference between revisions of "751.12 Barriers, Railings, Curbs and Fences"
m (→751.12.4 Chain Link Fence: Per Bridge, updated fencing details) |
m |
||
Line 877: | Line 877: | ||
| | | | ||
|- | |- | ||
− | |[[Image:751.12.4 details | + | |[[Image:751.12.4 details at expansion device gap.jpg|750px]] |
|- | |- | ||
!Details at Expansion Device Gap | !Details at Expansion Device Gap |
Revision as of 10:48, 27 February 2012
Contents
- 1 751.12.1 Standard Safety Barrier Bridge Curbs
- 2 751.12.2 Safety Barrier Bridge Curbs (NJ Shape)
- 2.1 751.12.2.1 General Design
- 2.2 751.12.2.2 Standard Reinforcement Details
- 2.3 751.12.2.3 End Bent Reinforcement
- 2.4 751.12.2.4 Slip-Form Reinforcement Details
- 2.5 751.12.2.5 SBC for Wing with Detached Wing Wall
- 2.6 751.12.2.6 Guard Rail Attachment Detail
- 2.7 751.12.2.7 Joint & Rustication Details
- 2.8 751.12.2.8 Plastic Waterstop
- 2.9 751.12.2.9 Details of Mounting Light Poles on Safety Barrier Curbs
- 2.10 751.12.2.10 Superelevation Details
- 2.11 751.12.2.11 Expansion Device Movement Gauge
- 3 751.12.3 Medians
- 4 751.12.4 Chain Link Fence
751.12.1 Standard Safety Barrier Bridge Curbs
751.12.1.1 Standard Safety Barrier Curbs used in Missouri
File:751.12 barrier curb - NJ Shape.gif | |
Type A Test Level TL-4 |
Type B Test Level TL-4 |
NJ Shape | |
---|---|
File:751.12 barrier curb - type c & d.gif | |
Type C Test Level TL-5 |
Type D Test Level TL-5 |
Note: | For Type F (Temporary Barrier Curb), refer to Missouri Standard Plans 617.20. |
---|---|
For Thrie Beam Rails, see Widening & Repair information. | |
See Structural Project Manager before using Type C or D barriers. |
751.12.2 Safety Barrier Bridge Curbs (NJ Shape)
751.12.2.1 General Design
New safety barrier curbs "shall be shown to be structurally and geometrically crashworthy". Therefore, the shape of the safety barrier curb is selected based on crash-tested, or equivalent crash-tested geometry.
The safety barrier curb used on new bridges shall be the 16” New Jersey (MO) safety shape barrier curb which has been crash-tested and FHWA approved as meeting test level TL-4.
Test level TL-4 shall be used for safety barrier curb design. TL-4 is defined by AASHTO as being “generally acceptable for the majority of applications on high-speed highways, freeways, expressways, and interstate highways with a mixture of trucks and heavy vehicles”.
Concrete | |
---|---|
Unit weight of reinforced concrete, | = 150 |
for modulus of elasticity, | = 145 |
Safety Barrier Curbs | |
Safety Barrier Curbs shall consist of: | |
Class B-1 Concrete | = 4.0 ksi |
= 8 | |
Median Barrier Curbs | |
Median Barrier Curbs shall consist of: | |
Class B-1 Concrete | = 4.0 ksi |
= 8 | |
Reinforcing steel | |
Minimum yield strength, | = 60.0 ksi |
Steel modulus of elasticity | = 29000 ksi |
751.12.2.2 Standard Reinforcement Details
R-Bar Required for Slip Form Option |
R1-Bar Shape 19 |
R2-Bar Shape 15 |
---|---|---|
R1 & R2-Bars permissible only when Slip Forming not allowed (*) | ||
16" Safety Barrier Curb |
(*) The single R bar adds to the rigidity of the reinforcement during construction and it is believed to help prevent cracking. The single bar also appears to assist maintaining uniform reinforcement cover.
Note: | Use same grade reinforcing steel in Barrier Curb as in slab. Splice length for #5 bars in Barrier Curb = 35". |
Dimensions shown are also typical for structures with latex or low slump concrete (except as indicated). |
751.12.2.3 End Bent Reinforcement
End Elevation | Elevation of Barrier Curb | ||
---|---|---|---|
Section A-A | Section B-B | Section C-C | |
* | Spaced with #5-K4 bars. | ||
** | Fit bar to follow transition face of curb. |
Elevation of Barrier Curb | ||||||
---|---|---|---|---|---|---|
End Elevation | Section A-A | Section B-B | ||||
* | Spaced with #5-K4 bars. | |||||
** | Fit bar to follow transition face of curb. | |||||
Section C-C | Section D-D |
End Elevation | Elevation of Barrier Curb | ||
---|---|---|---|
Section A-A | Section B-B | Section C-C | |
* | Spaced with #5-K4 bars. | ||
** | Fit bar to follow transition face of curb. |
751.12.2.4 Slip-Form Reinforcement Details
Section at End Bent (Optional Slip-Form Barrier) |
---|
Section Near Joints (Optional Slip-Form Barrier) |
Section A-A |
(*) Each side of Joint Location. |
NOTE TO DETAILER:
Optional Slip-Form Safety Barrier Curb details shall be placed on all jobs (except Prestressed Double-Tee Structures) where applicable.
Add #5 cross bracing bars for Slip-Form option. Base the length of these bars on the shortest distance between joints throughout the structure. Show the C-Bars in the Bar List and note that these bars are for the Slip-Form option only.
751.12.2.5 SBC for Wing with Detached Wing Wall
751.12.2.6 Guard Rail Attachment Detail
Part Elevation A-A | Part Elevation |
---|---|
Part Plan | |
Auxiliary View |
751.12.2.7 Joint & Rustication Details
Curb Expansion Joints. Openings required for expansion shall be provided in the barrier curb in conjunction with deck joints. For details of expansion joints in barrier curb see expansion device details.
Curb Joints. 1/4 in. joints are located in the barrier curb at locations of negative moments to prevent cracking in the barrier curb. These joints are required when decks are continuous over intermediate bents for both continuous and simple span structures. These joints are also required at the front face of integral end bents. For details of 1/4 in. curb joints at integral end bents see integral end bent details.
Rustication. Rustication shall be used on grade separations only. Rustication shall be terminated four feet from the end of the barrier curb.
* | One space = 1/4 Span to nearest 1 in. increment (Span < 40 ft.) |
One space = 10 ft. (Span = 40 ft. to 125 ft.) | |
Two spaces = 10 ft. (Span > 125 ft.) |
Optional Slip-Form Barrier Curbs | |
---|---|
Section A-A | Section Thru Joint |
Part Section Showing Placement of Joints |
Note: Rustication to be used on highway grade separation only. End rustication 4'-0" from end of wing. | |
Part Section Showing Rustication Details |
---|
751.12.2.8 Plastic Waterstop
To eliminate water seepage problems, use a plastic waterstop, as specified, and in accordance with details shown below.
Use a plastic waterstop at all safety barrier curb joints on grade separations, except over railroads and county roads.
Use a plastic waterstop on lower safety barrier curb joint only, for structures with superelevation on grade separations.
751.12.2.9 Details of Mounting Light Poles on Safety Barrier Curbs
751.12.2.10 Superelevation Details
"A" | = 2'-8" + (Superelev. Slope x 16") |
"B" | = 2'-8" - (Superelev. Slope x 16") |
"C" | = 8 1/2" + (Superelev. Slope x 16") |
"D" | = 8 1/2" - (Superelev. Slope x 16") |
751.12.2.11 Expansion Device Movement Gauge
All expansion joints shall be equipped with a movement gauge so an historical visual record showing total movement can be established.
Add following notes to plans:
Notes:
A movement gauge shall be provided on one side of bridge at all safety barrier curb expansion joints.
All steel shall be galvanized.
Cost of movement gauge, complete-in-place, shall be included in the contract unit price bid for Safety Barrier Curb.
751.12.3 Medians
751.12.3.1 Double Faced Median Barrier Curb (NJ Shape)
Note: | Use same grade reinforcing steel in barrier curb as in slab. |
Splice length for #5-R bars in barrier curb = 35". | |
Do not use this barrier curb over precast prestressed panels. |
Note to detailer: | Provide slip-form option for double faced median safety barrier curb. For slip-form option additional #5 cross bracing bars shall be placed on both sides of all joints and R2 bars shall be one bar. |
File:751.12 double-faced median barrier curb reinforcement-r2 bar.gif | File:751.12 double-faced median barrier curb reinforcement-r4 bar.gif |
R2 Bar Shape 15 |
R4 Bar Shape 27 |
---|---|
File:751.12 section thru double faced median barreir curb.gif | |
Section Thru Double Faced Median Barrier Curb | |
Twin Bridge Median Barrier Curb Details | |
File:751.12 section thru median curb with open joint.gif | |
Section Thru Median with Open Joint |
751.12.3.2 Concrete Median Curbs
File:751.12 concrete median curbs-open joint (twin bridges typ).gif |
Open Joint (Twin Bridges Typ.) |
---|
File:751.12 concrete median curbs-barrier class (no joint).gif |
Barrier Class (No Joint) |
File:751.12 concrete median curbs-mountable class.gif |
Mountable Class |
Note: All reinforcement shown shall be epoxy coated. |
Details shown are very general. Consult Design Layout for specific details for each individual structure. |
Bent Bar: | |
File:751.12 concrete median curbs (permissalbe alternates)-open joint (twin bridges typ.).gif | File:751.12 concrete median curbs (permissalbe alternates)-barrier class (no joint).gif |
Open Joint (Twin Bridges Typ.) | Barrier Class (No Joint) |
---|---|
File:751.12 concrete median curbs (permissalbe alternates)-detail a.gif | File:751.12 concrete median curbs (permissalbe alternates)-detail b.gif |
Detail "A" | Detail "B" |
File:751.12 concrete median curbs (permissalbe alternates)-field bent bar.gif | Add note to plans: |
No additional payment will be allowed for the usage of either alternate anchoring systems. | |
Resin Anchor: | |
File:751.12 concrete median curbs (permissalbe alternates)-resin anchor choice.gif | |
Note: All reinforcement shown shall be epoxy coated. |
751.12.4 Chain Link Fence
Superstructure Near Steps | |
---|---|
Superstructure at or Near End Panel | |
File:751.12 pedestrian overpass-superstructure near steps detail a.gif | Design Crieria: Fence fabric weight = 10#/lin. ft. Eff. wind area = 0.11 area/sq.ft. |
Detail "A" |
File:751.12 pedestrian overpass-landing.gif | File:751.12 pedestrian overpass-section thru fence.gif |
Landing | Section thru Fence |
---|---|
Details of Handrail Bracket | |
Rail Post Connection (Typical) | |
Plan of Floor Plate | |
Details of Expansion Device Gap | |
(**) May conflict with any proposed expansion device sidewalk, consult Structural Project Manager. | |
Typical Section Near Splice Gap | |
Note: 8'-0" max. post spacing for superstructure.
(*) Locate at about 30'-0" centers with at least one splice gap between pull posts. (Add the following notes to the plans.) |