This is the Engineering Policy Guide Test Site. To view the current EPG click here

Difference between revisions of "1070.3 Laboratory Testing Guidelines for Sec 1070"

From Engineering_Policy_Guide
Jump to navigation Jump to search
m (article construction)
 
Line 11: Line 11:
  
 
===1070.3.3 Sample Record===
 
===1070.3.3 Sample Record===
The sample record shall be completed in SiteManager, as described in [[106.10 Automation of Material Procedures|Automation Sec 3510]], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.9 Reporting Test Results|106.9 Reporting Test Results]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
+
The sample record shall be completed in SiteManager, as described in [[106.10 Automation of Material Procedures|Automation Sec 3510]], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.
  
  
 
[[Category:1070 Water]]
 
[[Category:1070 Water]]

Revision as of 12:51, 1 July 2010

1070 water.jpg

This article establishes procedures for Laboratory testing and reporting water that is to be used in mixing and curing Portland cement concrete, mortar and grout. Refer to Sec 1070 for MoDOT's specifications.

1070.3.1 Sample Preparation

Immediately prior to starting all tests on water, the sample as received in the laboratory should be agitated.

1070.3.2 Procedure

Chemical and physical tests on water samples shall be conducted according to the methods set forth in AASHTO T26. The pH test is performed according to standard laboratory practice. If the pH test shows that the sample is out of the acceptable pH range or if the sample contains oil, acid, alkali, salt, or organic matter, then determine the autoclave expansion and 7-day compressive strength as described in the specification. Original test data and calculations shall be recorded in Laboratory workbooks. Test results shall then be recorded through SiteManager.

1070.3.3 Sample Record

The sample record shall be completed in SiteManager, as described in Automation Sec 3510, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.