This is the Engineering Policy Guide Test Site and not up to date. Please visit the current Engineering Policy Guide here.

1070.3 Laboratory Testing Guidelines for Sec 1070: Difference between revisions

From Engineering Policy Guide
Smithk (talk | contribs)
m →‎1070.3.3 Sample Record: Per Cm, updated link
 
Smithk (talk | contribs)
m updated link
Line 2: Line 2:


This article establishes procedures for Laboratory testing and reporting water that is to
This article establishes procedures for Laboratory testing and reporting water that is to
be used in mixing and curing Portland cement concrete, mortar and grout.  Refer to [http://www.modot.mo.gov/business/standards_and_specs/Sec1070.pdf Sec 1070] for MoDOT's specifications.
be used in mixing and curing Portland cement concrete, mortar and grout.  Refer to [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1070] for MoDOT's specifications.


===1070.3.1 Sample Preparation===
===1070.3.1 Sample Preparation===

Revision as of 13:41, 15 June 2016

File:1070 water.jpg

This article establishes procedures for Laboratory testing and reporting water that is to be used in mixing and curing Portland cement concrete, mortar and grout. Refer to Sec 1070 for MoDOT's specifications.

1070.3.1 Sample Preparation

Immediately prior to starting all tests on water, the sample as received in the laboratory should be agitated.

1070.3.2 Procedure

Chemical and physical tests on water samples shall be conducted according to the methods set forth in AASHTO T26. The pH test is performed according to standard laboratory practice. If the pH test shows that the sample is out of the acceptable pH range or if the sample contains oil, acid, alkali, salt, or organic matter, then determine the autoclave expansion and 7-day compressive strength as described in the specification. Original test data and calculations shall be recorded in Laboratory workbooks. Test results shall then be recorded through SiteManager.

1070.3.3 Sample Record

The sample record shall be completed in SiteManager, as described in Automation Sec, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.