This is the Engineering Policy Guide Test Site. To view the current EPG click here

Independent Assurance Samples and Tests

From Engineering_Policy_Guide
Revision as of 11:42, 21 March 2011 by Smithk (talk | contribs) (→‎Guide Schedule for Independent Assurance Samples: Per Physical Lab, "Minimum Number of Tests" column removed.)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Guide Schedule for Independent Assurance Samples

If a local public agency obtains funds from MoDOT and will use MoDOT QC/QA practices, they should follow the guidelines in the Independent Assurance Samples and Tests table AND follow the guidelines for Federal-Aid Acceptance Sampling and Testing (FAST) when using materials that do not have the contractor QC of the QC/QA program (Stabilized Permeable Base or Modified subgrade).


Type of Construction or Material Tests to be Made (if specified) Sampled Tested In Comparison Limits
Grading - Embankment Density SAA003AA After compaction Field Dry weight (mass) per cubic foot (meter) within 6% of the mean of the two tests.(2)
Subgrade Preparation Density SAA003AA After compaction Field Dry weight (mass) per cubic foot (meter) within 6% of mean of the two tests.(2)
Aggregate Base (Roadway and Shoulders) (1),

Type 1, 5 or Stabilized Permeable Base.

Note: Gradation only for Stabilized Permeable base

Density SAA003DA After compaction Field Dry weight (mass) per cubic foot (meter) within 6% of mean of the two tests. (2)
Gradation SAA002EC SAA002GA SAA002HA Before compaction Field, district laboratory 1/2 gradation range
PI included with gradation Before compaction Field, district laboratory Within one (1) PI of their mean.
Modified Subgrade (sand-soil base, soil-cement base or soil-lime base) Gradation SAA002KA Before compaction Field, district laboratory 1/2 specification range.
Liquid Limit included with gradation. Before compaction Field, district laboratory Within 13% of their mean.
PI included with gradation. Before compaction Field, district laboratory Within one (1) PI of their mean.
Density SAA003AA After compaction Field Dry weight (mass) per cubic foot (meter) within 6% of the mean of the two tests.(2)
Plant Mix Bit. Base or Plant Mix Bit. Pavement

or

Ultra-Thin Bonded Wearing Surface(5)

Gradation/Del. SAA002IF Before mixing Field, district laboratory 1/2 specification range.
Density SAA003CA After compaction District laboratory, Central Laboratory Specific gravity within 2% of the mean of the two tests.
Asphalt Cement content by Nuclear Gauge SAA003ED Before compaction Field (3)
Superpave Asphaltic Concrete Pavement Gradation/Del. SAA002IF Before mixing Field, district laboratory 1/2 specification range.
Density SAA024AB After compaction District laboratory, Central Laboratory Specific gravity within 2% of the mean of the two tests.
Maximum Specific Gravity SAA024AB Before compaction Field Maximum specific gravity within 1% of the mean of the two tests.
Volumetric (Sp. Gr. of gyratory compacted specimens) SAA024AB Before compaction District laboratory, Central Laboratory Specific gravity within 2% of the mean of the two tests.
Asphalt Cement Content by Nuclear gauge or Binder Ignition Oven SAA024AB Before compaction Field (3)
Gyratory Compactor Before compaction Field (4)
Crushed Stone or Gravel Surfacing Gradation SAA002VB - Field, district laboratory 1/2 specification range
PCC Pavement or PCC Base

(Full Depth, Unbonded Overlay, Bonded overlay and Whitetopping)

Air Content SAA502BA - Field 1-1/2%
Slump included with air SAA502BA - Field One inch (25mm)
Pavement Thickness SAA502AA - Field, district laboratory, Central Laboratory (6)
Compressive Strength SAA502AA - Field, district laboratory, Central Laboratory (7)
Gradation (Coarse Aggregate) SAA002JF or SAA002JE Batch plant Field, district laboratory 1/2 specification range
Gradation (Fine Aggregate) SAA002AC Batch plant Field, district laboratory 1/2 specification range
Deleterious (Coarse Aggregate) included with gradation Batch plant Field, district laboratory 1/2 specification range
Concrete Masonry(Structures) Air Content SAE005CA (SAM005CA) - Field 1-1/2%
Slump included with air - Field One inch (25mm)
Compressive Strength SAA599AB - Central Laboratory Mean of either set within 15% of the mean of both sets.
Gradation (Coarse Aggregate) SAA002JF Batch plant Field, district laboratory 1/2 specification range.
Gradation (Fine Aggregate) SAA002AC Batch plant Field, district laboratory 1/2 specification range.
Deleterious (Coarse Aggregate) included with the gradation Batch plant Field, district laboratory 1/2 specification range.


FOOTNOTES

1. When aggregate base is shown in the contract to be measured and paid for by the area, convert the area to tons and follow the sampling frequency shown in this schedule. When converting use the factor 0.06 ton/sq.yd./1 in. (0.0028 Mg/sq.m.) thickness.

2. If nuclear method is used, observation only - no limits.

3. If nuclear method or binder ignition method used, observation only - no limits.

4. If an approved gyratory compactor is used, observation only - no limits.

5. Density test not applicable for Ultra-Thin Bonded Wearing Surface.

6. If an approved height measuring device is used, observation only - no limits.

7. If an approved compression machine is used, observation only - no limits.