This is MoDOT's Engineering Policy Guide Test Site. Do not use the information on this site. Click here to access MoDOT's current Engineering Policy Guide

Category:710 Epoxy Coated Reinforcing Steel

From Engineering_Policy_Guide
Jump to navigation Jump to search

710.1 Construction Inspection for Sec 710

Shipping damage
Epoxy splitting

Those provisions of Sec 706 concerning placement and location of reinforcing steel apply to epoxy coated reinforcing steel. The reinforcing steel should be inspected for damage to the coating. Any damaged areas should be repaired with epoxy patching material furnished by the manufacturer.

While torch cutting is acceptable to shorten uncoated resteel, in no case should a torch be used on epoxy coated resteel. Any long epoxy bars should be saw cut and the ends patched with patching material approved by the coating manufacturer.

During placement the inspector should caution the contractor not to damage the coating and make sure the proper vibrators are used.

Structural Steel Coatings
Structural Steel Coatings for Corrosion Mitigation, 2010
Coated Steel Rebar, Enamel
Coated Steel Rebar for Enhanced Concrete-Steel Bond Strength and Corrosion Resistance, 2010
See also: Research Publications